LIS总是看不懂,哪位高人指点一下?
You lose, fella. The EMTP logic has detected an error condition, and is now going to terminate program execution.The followingmessage summarizes the circumstances leading to this situation.Where an otherwise-unidentified data card is referred to, or where
the "last" card is mentioned, it is the most recently read card of the input data that is meant.The 80-column image of this card
is generally the last one printed out prior to this termination message.But possibly this last-read card has not yet been
displayed, so a copy follows:
"X0005AX0005A MEASURING 1"
KILL code number Overlay number Nearby statement number
224 4 8212
KILL = 224. The last-read data card is for a switch that has both terminals connected to the same nodeBUS1 = X0005A. This is
objectionably stupid.
哪位高人能说一下,上面是什么意思啊?自己总是琢磨不透,谢谢了~ 他是说你的一个开关的两端连在同一个节点X0005A上面。。。。。。
“The last-read data card is for a switch that has both terminals connected to the same nodeBUS1 = X0005A. This is objectionably stupid.” file:///C:/Documents%20and%20Settings/Administrator/Application%20Data/Tencent/Users/569290572/QQ/WinTemp/RichOle/$M7C37SG1[}N82_`K{8HKZQ.jpg
图如上该怎么改呢?我实在不明白。 不好意思,不太会弄,这是图 回复 4# jymildred
你吧那个支路电流元件两端的连线拆了然后一端连线路一端连开关 试试最好不要直接把电流测量元件直接放支路上 回复 4# jymildred 把电流互感器两端的名称改一下试试吧?名字不应该是一样的啊……