MAGICALMT 发表于 2012-4-29 16:29:59

MATLAB/Simulink电力系统潮流计算仿真

《MATLAB/Simulink电力系统建模与仿真》中94页中的2机5节点电力系统潮流计算仿真,我参数完全按照书中设置,但调试有问题,Update Load Flow之后,得出发电机的三相电压不对称,数据如注释所示。哪位高手知道为啥?
注:
Machine:    G2                                 
Nominal:    100 MVA   10.5 kV rms               
Bus Type:   Swing bus                           
Uan phase:-40.27°                           
Uab:      52029 Vrms -10.27°      
Ubc:      48895 Vrms 157.70°      
Uca:      11025 Vrms -122.71°      
Ia:         16777 Arms -9.91°      
Ib:         16777 Arms -129.91°      
Ic:         16777 Arms 110.09°      
P:          1.3046e+009 W            
Q:          -7.6415e+008 Vars   [-7.642 pu]   
Pmec:       1.3079e+009 W            
Torque:   8.3264e+006 N.m         
Vf:         6.067 pu                           
                                                
Machine:    G1                                 
Nominal:    100 MVA   10.5 kV rms               
Bus Type:   P & V generator                     
Uan phase:-40.45°                           
Uab:      55176 Vrms -10.45°      
Ubc:      50638 Vrms 158.65°      
Uca:      11025 Vrms -130.09°      
Ia:         17338 Arms -21.32°      
Ib:         17338 Arms -141.32°      
Ic:         17338 Arms 98.68°      
P:          1.5654e+009 W            
Q:          -5.4297e+008 Vars   [-5.43 pu]      
Pmec:       1.569e+009 W            
Torque:   9.9887e+006 N.m         
Vf:         6.7898 pu                           
                                                
Machine:    Load3                              
Nominal:    115 kV rms                        
Bus Type:   P & Q load                        
Uan phase:-46.14°                           
Uab:      6.2602e+005 Vrms -16.14°
Ubc:      6.1132e+005 Vrms 161.43°
Uca:      30061 Vrms -136.62°   
Ia:         300.16 Arms-102.68°               
Ib:         300.16 Arms137.32°               
Ic:         300.16 Arms17.32°               
P:          1.7944e+008 W                     
Q:          2.7153e+008 Vars                  
                                                
Machine:    Load2                              
Nominal:    115 kV rms                        
Bus Type:   P & Q load                        
Uan phase:-41.18°                           
Uab:      6.0512e+005 Vrms -11.18°
Ubc:      5.7431e+005 Vrms 157.92°
Uca:      1.1609e+005 Vrms -121.95°
Ia:         798.9 Arms-92.72°               
Ib:         798.9 Arms147.28°               
Ic:         798.9 Arms27.28°                  
P:          5.2087e+008 W                     
Q:          6.5561e+008 Vars                  
                                                
Machine:    Load1                              
Nominal:    115 kV rms                        
Bus Type:   P & Q load                        
Uan phase:-40.94°                           
Uab:      6.3759e+005 Vrms -10.94°
Ubc:      5.8926e+005 Vrms 158.63°
Uca:      1.2147e+005 Vrms -129.49°
Ia:         433.21 Arms-97.84°               
Ib:         433.21 Arms142.16°               
Ic:         433.21 Arms22.16°               
P:          2.6123e+008 W                     
Q:          4.0079e+008 Vars

chenbo0623 发表于 2012-5-25 22:06:54

如果楼主的问题还没有解决,不妨把模型和参数设置发我邮箱orchis1986@126.com,我会尽快给你回复。

MAGICALMT 发表于 2012-5-26 07:23:24

回复 2# chenbo0623
谢谢,已经解决。

MAGICALMT 发表于 2012-5-26 07:24:58

回复 2# chenbo0623
知道互联系统潮流计算有什么特别么?和单区域潮流计算相比?请看我的求助。谢谢!

蓝白灵魂 发表于 2012-11-29 21:12:03

回复 2# chenbo0623


   您好,我在搭这个模型,仿真时总是有错误,能否帮我看下,谢谢

rockhq 发表于 2012-12-4 14:03:31

看了那,柯布额可以.

redplum 发表于 2012-12-4 14:14:47

再次感谢楼主

d123456kw 发表于 2012-12-4 22:26:49

这个问题怎么解决的啊

ferxiang 发表于 2012-12-5 03:53:10

回复 4# MAGICALMT


    网络结构突然变化,本来两边平衡机各自平衡系统的,突然结构的改变可能引起大范围的潮流转移。楼主可以自己拼几个系统试试

THOR 发表于 2018-4-25 20:10:49

怎么解决的,我也是这个问题