ATP新手
ATP新手,点plotxy后出现The selected file contains no bytes,如下,求大神解答Alternative Transients Program (ATP),GNU Linux or DOS.All rights reserved by Can/Am user group of Portland, Oregon, USA.
Date (dd-mth-yy) and time of day (hh.mm.ss) = 02-May-1921:15:23 Name of disk plot file isjjj1.pl4
Consult the 860-page ATP Rule Book of the Can/Am EMTP User Group in Portland,Oregon, USA.Source code date is 19 September 2003.
Total size of LABCOM tables = 9872109 INTEGER words.31 VARDIMList Sizes follow:600210K192K900420K120015K
120K2250380072012007280051090K80090254120K100K3K15K192K12030K160K600210K30019200
--------------------------------------------------+--------------------------------------------------------------------------------
Descriptive interpretation of input data cards. |Input data card images are shown below, all 80 columns, character by character
0 1 2 3 4 5 6 7 8
012345678901234567890123456789012345678901234567890123456789012345678901234567890
--------------------------------------------------+--------------------------------------------------------------------------------
Comment card. KOMPAR > 0. |C data:JJJ1.ATP
Marker card preceding new EMTP data case. |BEGIN NEW DATA CASE
Comment card. KOMPAR > 0. |C --------------------------------------------------------
Comment card. KOMPAR > 0. |C Generated by ATPDRAW五月, 星期四 2, 2019
Comment card. KOMPAR > 0. |C A Bonneville Power Administration program
Comment card. KOMPAR > 0. |C by H. K. H鴌dalen at SEfAS/NTNU - NORWAY 1994-2015
Comment card. KOMPAR > 0. |C --------------------------------------------------------
Comment card. KOMPAR > 0. |CdT>< Tmax >< Xopt >< Copt ><Epsiln>
Misc. data. 1.000E-09 1.000E-03 0.000E+00 | 1.E-9 .001
Misc. data. 500 111100100 | 500 1 1 1 1 0 0 1 0
Comment card. KOMPAR > 0. |C 1 2 3 4 5 6 7 8
Comment card. KOMPAR > 0. |C 345678901234567890123456789012345678901234567890123456789012345678901234567890
Comment card. KOMPAR > 0. |C < n1 >< n2 ><ref1><ref2>< R>< L>< C>
Comment card. KOMPAR > 0. |C < n1 >< n2 ><ref1><ref2>< R>< A>< B><Leng><><>0
Series R-L-C. 0.000E+000.000E+002.500E-04 |XX0001 250. 0
4.000E+00 6.000E+01 3.000E+08 6.000E+01 1.667E-06|-1XX0001XX0003 4. 60.3.E8500. 1 0 0
Series R-L-C. 0.000E+001.000E-010.000E+00 |XX0002XX0001 100. 0
4.000E+00 6.000E+01 3.000E+08 6.000E+01 1.667E-06|-1XX0006XX0007 4. 60.3.E8500. 1 0 0
4.000E+00 6.000E+01 3.000E+08 6.000E+01 1.667E-06|-1XX0008XX0005 4. 60.3.E8500. 1 0 0
Series R-L-C. 2.000E+005.000E-070.000E+00 |XX0003XX0004 2. .0005 0
4.000E+00 6.000E+01 3.000E+08 6.000E+01 1.667E-06|-1XX0005XX0009 4. 60.3.E8500. 1 0 0
4.000E+00 6.000E+01 3.000E+08 6.000E+01 1.667E-06|-1XX0008XX0006 4. 60.3.E8500. 1 0 0
4.000E+00 6.000E+01 3.000E+08 6.000E+01 1.667E-06|-1XX0010XX0008 4. 60.3.E8500. 1 0 0
Series R-L-C. 0.000E+000.000E+002.500E-04 |XX0006 250. 0
Series R-L-C. 0.000E+000.000E+002.000E-03 |XX0007 2.E3 0
Series R-L-C. 0.000E+001.000E-010.000E+00 |XX0007XX0011 100. 0
Blank card ending branches.IBR, NTOT = 1212 |BLANK BRANCH
Comment card. KOMPAR > 0. |C < n 1>< n 2>< Tclose ><Top/Tde >< Ie ><Vf/CLOP ><type>
Switch. 0.00E+000.00E+000.00E+000.00E+00|76XX0004XX0005 STATISTICS 0
------------------------------------------------------------------------------------------------------------------------------------
ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/
ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/
------------------------------------------------------------------------------------------------------------------------------------
You lose, fella. The EMTP logic has detected an error condition, and is now going to terminate program execution.The following
message summarizes the circumstances leading to this situation.Where an otherwise-unidentified data card is referred to, or where
the "last" card is mentioned, it is the most recently read card of the input data that is meant.The 80-column image of this card
is generally the last one printed out prior to this termination message.But possibly this last-read card has not yet been
displayed, so a copy follows:
"76XX0004XX0005 STATISTICS 0"
KILL code number Overlay number Nearby statement number
141 4 3356
KILL = 141. STATISTICSorSYSTEMATIC(the two 10-letter request words) can legally be keyed in columns 55-64 of a switch card.
This would be as part of a data case that has integer miscellaneous data parameterNENERGnonzero (a value of0 was read from
the user`s data). However, for positive NENERG,only"STATISTICS"is allowed;for negative NENERG,only"SYSTEMATIC"is
allowed;and for zero NENERG,neither request word may be used.
------------------------------------------------------------------------------------------------------------------------------------
ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/
ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/ERROR/
------------------------------------------------------------------------------------------------------------------------------------
Actual List Sizes for the preceding solution follow. 02-May-1921:15:23
Size1-10: -9999 -9999 -9999 -9999 -9999 -9999 -9999 -9999 0 0
Size 11-20: -9999 -9999 -9999 -9999 -9999 -9999 -9999 -9999 23 0
Size 21-30: 1 -9999 -9999 -9999 -9999 1 -9999 -9999 -9999 0
Seconds for overlays1-5: 0.000 0.000 0.000-- (CP: Wait; Real)
Seconds for overlays6-11 : 0.000 0.000 0.000
Seconds for overlays 12-15 : 0.000 0.000 0.000
Seconds for time-step loop : 0.000 0.000 0.000
Seconds after DELTAT-loop: 0.016 0.000 0.016
---------------------------
Totals: 0.016 0.000 0.016 <span style="color:#444444;font-family:Tahoma, &quot;font-size:14px;background-color:#FFFFFF;">出现 ERROR/ERROR/ERROR 表示电路部分有错误,计算报错了 当然是PL4文件没数据了,具体什么错误要大牛解答 高压直流输电线路
页:
[1]